Brand Name : inntronic
Model Number : IPW6C
Place of Origin : China
MOQ : 1pc
Payment Terms : L/C
Delivery Time : 15-30 days
Price : Negotiable
pattern : Single Point Load Cell
Capacity : 3kg to 40kg
output : 2mv/v
Material : Aluminum load cell
Application : static weighing
interchangeable beand : HBM
IP protection standard : IP67
accuracy grade : C3
Non-linearity : 0.0166
Output impedance : 130*25.4*22
40kg Counting Scale Portable Load Cell Sensor For Weight Measurement ODM
-- Accuracy class C3 with OIML-R60 test report
-- Off center load compensated (OIML R 76)
-- Max. capacities: 3 kg ... 40 kg
-- Degree of protection IP67(according to EN 60 529)
-- Shielded connection cable
-- Optimized for static weighing applications
-- Accuracy class C6 with OIML-R60 test report
-- Connection cable in six wire circuit
-- Different cable lengths
− Aligned output, suitable for connectionin parallel
| Type | IPW6C | ||||||||
| Accuracy class1) | C3; C3MR | ||||||||
| Number of load cell intervals (nLC) | 3000 | ||||||||
| Maximum capacity (Emax)2)) | kg | 3 | 5 | 10 | 15 | 20 | 30- | 40 | |
| Minimum LC verification interval (vmin) Accuracy class C3 | g | 10 | 10 | 20 | 20 | 50 | 50 | 50 | |
| Temperature effect on zero balance (TK0) Accuracy class C3
| % v. Cn / 10 K
| ±0.0233 | ±0.0280 | ±0.0280 | ±0.0186 | ±0.0350 | ±0.0233 | ±0.0350 | |
| Minimum LC verification interval (vmin) Accuracy class C3MR | g | 0.2 | 0.5 | 1 | 1 | 2 | 2 | 5 | |
| Temperature effect on zero balance (TK0) Accuracy class C3MR | % v. Cn / 10 K
| ±0.0093 | ±0.0140 | ±0.0140 | ±0.0093 | ±0.0140 | ±0.0093 | ±0.0175 | |
| Max. platform size | mm | 300 x 300 | |||||||
| Sensitivity (Cn) | mV/V | 2.0±0.2 | |||||||
| Zero balance | 0±0.12 | ||||||||
| Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] | % v. Cn / 10 K
| ±0.0175 ±0.0117 | |||||||
| Hysteresis error (dhy)3) | % of Cn | ±0.0166 | |||||||
| Non-linearity (dlin)3) | ±0.0166 | ||||||||
| Minimum dead load output return (DR) | ±0.0245 | ||||||||
| Off center load error4) | ±0.0233 | ||||||||
| Input resistance (RLC) | Ω | 300 ... 500 | |||||||
| Output resistance (R0) | 300 ... 500 | ||||||||
| Reference excitation voltage (Uref) | V | 5 | |||||||
| Nominal range of excitation voltage (BU) | 1...12 | ||||||||
| Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | |||||||
| Nominal temp. range (BT) | °C [°F] | −10 ... +40 [+14 ... +104] | |||||||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | ||||||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | ||||||||
| Safe load limit (EL ), at max. 100mm eccentricity | % of Emax | 150 100 | |||||||
| Lateral load limit (Elq), static | % of Emax | 300 | |||||||
| Breaking load (Ed) | 300 | ||||||||
| Deflection at Emax (snom), approx. | mm | < 0.5 | |||||||
| Weight (G), approx. | kg | 0.25 | |||||||
| Protection class according to EN 60 529 (IEC 529) | IP67 | ||||||||
| Material: Measuring element Coating Cable sheath | Aluminum Silicone rubber PVC | ||||||||





|
|