Brand Name : inntronic
Model Number : IPW2D
Place of Origin : China
MOQ : 1pc
Payment Terms : L/C
Delivery Time : 15-30 days
Price : Negotiable
Type : Single Point Load Cell
Capacity : 7.2kg to 72kg
Output : 2mv/v
Material : Aluminum
Application : static weighing
Interchangeable brand : HBM
IP Protection standard : IP67
Accuracy grade : C3
Hysteresis error : 0.0166
Non-linearity : 0.0166
− Accuracy class C3 with OIML-R60 test report
− Max. capacities: 7.2 kg ... 72 kg
− Off center load compensated(OIML R76)
− Degree of protection IP67(according to EN 60 529)
− Shielded connection cable
− optimized for dynamic weighing applications
− Connection cable in six wire circuit
− Different cable lengths
− Aligned output, suitable for
− Aligned output, suitable for connectionin parallel
| Type | IPW2D | ||||||
| Accuracy class1) | C3; C3MR | ||||||
| Number of load cell intervals (nLC) | 3000 | ||||||
| Maximum capacity (Emax)2)) | kg | 7.2 | 12 | 18 | 36 | 72 | |
|  			 Minimum LC verification interval (vmin) Accuracy class C3  |  			g | 1 | 2 | 5 | 10 | 20 | |
|  			 Temperature effect on zero balance (TK0) Accuracy class C3 
  |  			 			 % v. Cn / 10 K 
  |  			±0.0194 | ±0.0233 | ±0.0389 | ±0.0389 | ±0.0389 | |
|  			 Minimum LC verification interval (vmin) Accuracy class C3MR  |  			g | 0.5 | 1 | 2 | 5 | 10 | |
|  			 Temperature effect on zero balance (TK0) Accuracy class C3MR  |  			 			 % v. Cn / 10 K 
  |  			±0.0097 | ±0.0116 | ±0.0155 | ±0.00194 | ±0.0194 | |
| Max. platform size | mm | 380 x 380 | |||||
| Sensitivity (Cn) | mV/V | 2.0±0.2 | |||||
| Zero balance | 0±0.1 | ||||||
|  			 Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉]  |  			 			 % v. Cn / 10 K 
  |  			 			 ±0.0175 ±0.0117  |  		|||||
| Hysteresis error (dhy)3) | % of Cn | ±0.0166 | |||||
| Non-linearity (dlin)3) | ±0.0166 | ||||||
| Minimum dead load output return (DR) | ±0.0166 | ||||||
| Off center load error4) | ±0.0233 | ||||||
| Input resistance (RLC) | Ω | 300 ... 500 | |||||
| Output resistance (R0) | 300 ... 500 | ||||||
| Reference excitation voltage (Uref) | V | 5 | |||||
| Nominal range of excitation voltage (BU) | 1 ... 12 | ||||||
| Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | |||||
| Nominal temp. range (BT) |  			 °C [°F]  |  			−10 ... +40 [+14 ... +104] | |||||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | ||||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | ||||||
|  			 Safe load limit (EL ), at max. 100mm eccentricity  |  			 			 % of Emax  |  			 			 150 160  |  		|||||
| Lateral load limit (Elq), static |  			 % of Emax  |  			300 | |||||
| Breaking load (Ed) | 300 | ||||||
| Weight (G), approx. | kg | 0.25 | |||||
|  			 Protection class according to EN 60 529 (IEC 529)  |  			IP67 | ||||||
|  			 Material: Measuring element Coating Cable sheath  |  			 			 Aluminum Silicone rubber PVC  |  		||||||




| 
                                             | 
                
                        Single point Load Cell IPW2D 72kg C3 Dynamic Weighing force sensor weight sensor 2mv/v for Digital Scale Aluminum IP67 Images |